Data Centre Fire Suppression System

Fire Detection and Suppression

Very Early Smoke Detection Apparatus (VESDA) is installed in every facility. These highly sensitive aspirating smoke detectors are linked to the Building Management system which is monitored continually from a network operations centre, provide very early detection to help avoid fire, loss and business disruption. This is coupled with a gas based fire retardant that is environmentally friendly, to put out fires instantly, without damaging equipment.

The Building Management System

Building Management System (BMS)

All facilities operate computerised building management systems that monitor and remotely operate sensors covering electrical, mechanical, fire detection and leak detection systems.

Data Centre Cooling System

Air Conditioning

To ensure optimum performance, all data floors are maintained at a constant 21°C ± 2°C and relative humidity is kept at 50% ± 10%. Both are continually monitored via the BMS.

N+1 Power Supplies

Power

Our policy guarantees all our customers a redundant high-capacity, stable and reliable power supply, with easy scalable expansion in the future. A minimum of 1Kw per square metre secure power is available, with power isolated between customer and maintained indefinitely, plus on-site generation which can deal with both customer and plant load whilst recharging the UPS.

All our facilities are built to at least an N+1 standard. This means that if two generators are required to provide non-stop power, then three are installed.

Diesel Generators

Backup Batteries and Diesel Generators

Battery sets keep the power on until the generators are up to working temperature. There is a 24 hour supply of diesel on site. The batteries are inspected every 4 hours and the entire system is run each month.

Data Centre Server Racks

Server Racks

Each rack is locked and measures a standard 42U high. Shelves can be provided if required.

Physical Security is tight

Physical Security

All datacentres feature totally comprehensive 24/7 security to keep your equipment 100% safe. This means our customers have the protection of security barriers, 24x7x365 monitoring by on-site personnel to include visual verification of all persons entering the building, CCTV video camera surveillance and a security breach alarm provides the control room with information.

Access to the facilities

Access

Access to the buildings, data floors and individual areas are via individually programmed Proximity Access Cards (PAC), usage of the PAC is logged centrally by time and date.
The cards cannot be used by anyone else, whenever you swipe your card tag over the sensors to gain access to the building, your digital photograph will be displayed on our security systems which are continuously monitored by our on-site technicians. The technicians will then verify the information and only when satisfied, allow access.

Quick Links »

Domain Name Search »

Has your domain name been taken?

Macromedia Alliance Partner Copyright © 1998 - 2008 Firstserv Limited. All rights reserved.


Macromedia Alliance Partner Home | Site Map |  Terms and Conditions | Acceptable Use Policy | Privacy Statement
Copyright © 1998 - 2008 Firstserv Limited. All rights reserved.
Firstserv, 12-13 Skylines, Limeharbour, Docklands, London E14 9TS, UK

Shared Web Hosting UK | Dedicated Server UK | UK Colocation | ColdFusion MX Hosting | JRun Hosting | Flash Communication Server MX Hosting | ASP.NET Hosting | Oracle Hosting | PHP Hosting UK | Dedicated Web Hosting UK | UK Web Hosting